Routine Maintenance Checklist
Routine maintenance of an electric injection molding machine is like refueling a car regularly:
- Lubrication System: Check the guide rail oil level weekly and use lubricant of appropriate viscosity.
- Electrical Components: Clean dust from the control cabinet monthly and check the tightness of wiring terminals.
- Moving Components: Adjust belt tension quarterly to ensure the transmission system is free from abnormal vibration.
In-depth Maintenance of Core Components
Maintenance Cycles for Three Key Components:
- Injection Unit: Replace the screw seal every 2000 hours.
- Mold Closing Mechanism: Check the platen parallelism every 5000 hours.
- Hydraulic System: Replace the filter element every six months.